Model TMC A6 hyper-jet (heats 50 – 80 – 100 square meters)

Classic model: 2 years full warranty
Comfort model: 5 years full warranty and preparation for capacity expansion + 1 module
Why heat pumps Termocasa are the best sellers on the market:
- The only air-to-water heat pumps with up to 5 years full warranty
- The best quality-price ratio, i.e. prices without competition
- The first heat pumps that do not stop during defrosting, but provide heat continuously
- The best performance in relation to the competition
- The first and only pumps on the market built from individual modules (multimodular) that work in cascade
- The first and only pumps on the market that use the Ultraflex heat exchanger Termocasa with up to 5 independent channels
TECHNICAL DATA TMC A12 hyper-jet HEAT PUMP
Technical data | TMC A6 | TMC A12 | TMC A18 | TMC A24 |
---|---|---|---|---|
Rated input power kw/h | 0,16 – 3,1 | 0,16 – 6,2 | 0,16 – 9,3 | 40,16 – 12,4 |
Heating power kw/h | 1,6 – 8,8 | 1,6 – 17,6 | 1,6 – 26,4 | 1,6 – 35,2 |
Minimum operating temperature °C | -30 | -30 | -30 | -30 |
Compressor performance coefficient max. PURPOSE | 5.1 | 5.1 | 5.1 | 5.1 |
Noise level (decibels) | 60 | 60 | 60 | 60 |
Compressor | Full DC Inverter | Full DC Inverter | Full DC Inverter | Full DC Inverter |
V / Hz power supply | TBU | TBU | TBU | TBU |
Refrigerant (optionally added) | R32 | R32 | R32 | R32 |
Ultraflex heat exchanger (galvanic optional) | Pipe in pipe | Pipe in pipe | Pipe in pipe | Pipe in pipe |
Pressure protection | HP / LP | HP / LP | HP / LP | HP / LP |
Internet or radio control | Optional | Optional | Optional | Optional |
Transport weight Kg | 20 + 50 | 20 + 50 + 50 | 20 50 + + + 50 50 | 20+50+50+50+50 |
Dimensions / dimensions cm (without rear connections) | H65-L70-L65 | H65-L70-L65 | H65-L70-L65 | H65-L70-L65 |
COP [W / W] compressor
tc\te | -20 | -15 | -10 | -5 | 0 | 5 | 10 |
---|---|---|---|---|---|---|---|
30 | 1.96 | 2.51 | 3.15 | 3.90 | 4.78 | 5.82 | 7.07 |
35 | 1.64 | 2.12 | 2.68 | 3.34 | 4.09 | 4.97 | 6.00 |
40 | 1.36 | 1.78 | 2.27 | 2.84 | 3.50 | 4.25 | 5.13 |
45 | - | 1.47 | 1.90 | 2.39 | 2.97 | 3.62 | 4.37 |
50 | - | - | 1.56 | 1.99 | 2.49 | 3.06 | 3.71 |
55 | - | - | - | 1.64 | 2.07 | 2.56 | 3.12 |
60 | - | - | - | - | 1.69 | 2.11 | 2.60 |
65 | - | - | - | - | 1.35 | 1.72 | 2.13 |
Tc – condensation temperature
The air-water heat pumps are equipped with Inverter compressors with powers starting from 6 KW thermal to industrial ones.
Heat pumps Termocasa are powered at 230V or 380V, stable and uninterruptible source, protected with grounding, and in case the supply voltage variation is greater than +/-3%, a voltage stabilizer will be installed.
Heating temperature can rise up to 60°C.